Features Include:
  • Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours,
  • Duty Cycle, Pulse Width and pulse Repetition Frequency
  • Status Indicators: Power On, Standby, RF On/Operate,
  • Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
  • Controls: Power On/Off, Standby, RF On/Operate, Fault Reset, Local/Remote
  • Ease of Maintenance
  • Designed to meet the safety requirements of the IEC-348 and Underwriters Labratory of American Standards
  • Broadband Coverage
  • Applications Include: MIL-STD-461/462, RTCA/D0-160, SAE Specifications, Radiated Susceptibility, Bellcore testing, Broadband Communications
  • Ruggedized Versions are available for Shipboard and Airborne applicatio


Models And Specifications
Model
Number
Freq
Range
(GHz
)
Min Pwr
Out*
(Watts)
Min Sat
Gain*
(dB)
Max
NF
(dB)
GT21-200
1-2
200
53
35
GT21-250
1-2
250
54
35
GT251-500
1-2.5
500
57
35
GT281-200
1-2.8
200
53
35
GT281-250
1-2.8
250
54
35
GT42-200
2-4
200
53
35
GT42-250
2-4
250
54
35
GT7525-500
2.5-7.5
500
57
35
GT84-200
4-8
200
53
35
GT84-250
4-8
250
54
35
GT84-500
4-7.5
500
57
35
7.5-8
450
57
35
GT825-200
2.5-8
200
53
35
GT128-200
8-12
200
53
35
GT188-200
7.5-18
200
53
35
GT188-250
7.5-18
250
54
35
GT188-300
7.5-18
300
55
35
GT188-500
7.5-18
500
57
35
GT1812-200
12-18
200
53
35
GT186-200
6-18
200
53
35
GT186-250
6-18
250
54
35
GT186-300
6-18
300
55
35
*Higher output power and gains available
IFI Amplifiers Option List


Top Of Page


Page 2 Additional Specifications