Features Include:
  • Digital Display Monitors: Power Supply Currents, Voltage, Forward RF Power, Reflected RF Power,(Optional on all models)Total Hours, Operate Hours,
  • Status Indicators: Power On, Standby, Operate,
  • Faults:Overcurrent, VSWR Overload, Thermal Overloads, Air Flow
  • Controls: Power On/Off, Standby, Operate, Fault Reset, Local/Remote
  • Ease of Maintenance
  • Designed to meet the safety requirements of the IEC-348 and Underwriters Labratory of American Standards
  • Broadband Coverage
  • Applications Include: MIL-STD-461/462, RTCA/DO-160, SAE Specifications, Radiated Susceptibility, Bellcore testing, Broadband Communications
  • Ruggedized Versions are available for Shipboard and Airborne applications
Models And Specifications
Model
Number
Freq
Range
(MHz)
Min Pwr
Out*
(Watts)
Min Sat
Gain*
(dB)

Rack
TYPE

M10*
.01-220
10
40
A
M50*
.01-220
50
47
A
M75*
.01-220
75
48
A
M100*
.01-220
100
50
A
M423
.01-220
300
55
C
M404
.01-220
500
57
C
M406
.01-220
1000
60
C
TCCX2000
.01-220
2000
63
D
TCCX2200
.01-220
2200
63
D
TCCX2500
.01-220
2500
64
D
TCCX3500
.01-100
3500
66
D
TCCX4500
.01-100
4500
67
D
SCCX10
.01-220
10
40
A
SCCX25
.01-220
25
44
A
SCCX50
.01-220
50
47
A
SCCX75
.01-220
75
48
A
SCCX100
.01-220
100
50
A
SCCX200 .01-220 200 53 B
SCCX250
.01-220
250
54
B
SCCX500
.01-220
500
57
B

*These models have no display and No GPIB Remote
IFI Amplifiers Option List