Features Include:
  • Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours, Duty Cycle, Pulse width, Pulse Repetition Frequency
  • Status Indicators: Power On, Standby, RF On/Operate
  • Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
  • Controls: Power On/Off, Standby, RF On/Operate, Fault Reset, Local/Remote
  • Ease of Maintenance
  • Designed to meet the safety requirements of the IEC-348 and Underwriters Labratory of American Standards
  • Broadband Coverage
  • Applications Include: MIL-STD-461/462, RTCA/DO-160, SAE Specifications, Radiated Susceptibility, Bellcore testing, Broadband Communications
  • Ruggedized Versions are available for Shipboard and Airborne applications


Models And Specifications
Model
Number
Freq
Range
(GHz
)
Min Pwr
Out*
(Watts)
Min Sat
Gain*
(dB)
Max
NF
(dB)
PT1412-5KW 1.2-1.4 5.0 67 35
PT1412-6KW 1.2-1.4 6.0 68 35
PT3525-5KW 2.5-3.5 5.0 67 35
PT4830-5KW 3.0-4.8 5.0 67 35
PT5727-4KW 2.7-5.7 4.0 66 35
PT128-3KW 8.2-12.4 3.0** 65 35
PT108-6KW 8.7-10.5 6.0 68 35
PT1715-4KW 15-17 4.0** 66 35
PT9593-4KW 9.3-9.5 4.5 66 35
PT128-8KW 8-12 8.0 69 35
PT1093-5KW 9.3-10 5.0 67 35

*Higher output power and gains available
**Over majority Of Frequency Range

IFI Amplifiers Option List


Top Of Page


Page 2 Additional Specifications