Features Include:
  • Digital Display Monitors: Collector Current, Collector Voltage, Helix Current, Helix Voltage, Forward RF Power, Reflected RF Power, Filament Hours, Beam Hours,
  • Status Indicators: Power On, Standby, RF On/Operate
  • Faults: Helix Overcurrent, VSWR Overload, Thermal Overloads, Air Flow, Collector Overcurrent
  • Controls: Power On/Off, Standby, RF On/Operate, Fault Reset, Local/Remote
  • Ease of Maintenance
  • Designed to meet the safety requirements of the IEC-348 and Underwriters Labratory of American Standards
  • Broadband Coverage
  • Applications Include: MIL-STD-461/462, RTCA/D0-160, SAE Specifications, Radiated Susceptibility, Bellcore testing, Broadband Communications
  • Ruggedized Versions are available for Shipboard and Airborne applications


Models And Specifications
Model
Number
Freq
Range
(GHz
)
Min Pwr
Out*
(Watts)
Min Sat
Gain*
(dB)
Max
NF
(dB)
T2618-5 18-26.5 5 37 35
T2618-10 18-26.5 10 40 35
T2618-25 18-26.5 25 44 40
T2618-40 18-26.5 40 46 40
T2618-50 18-26.5 50 47 40
T4026-10 26.5-40 10 40 40
T4026-25 26.5-40 25 44 40
T4026-40 26.5-40 40 46 40
T4026-50 26.5-40 50 47 40
T3832-40 32-38 40 46 40
T3832-60 32-38 60 48 40
T3027-120 27.5-30 120 52 38
T3027-150 27.5-30 150 53 35
*Higher output power and gains available
IFI Amplifiers Option List