Prime
Power:
115/208 or 200/220/230/240VAC
±10% 50/60 Hz, three phase Wye, Delta and/or 400 Hz power is
available.
|
|
Mechanical:
|
| Rack
Dimensions: |
See Outline Below |
| Weight:
|
See
below |
| Cooling:
|
Internal
forced air |
Remote Operation:
GPIB,
RS422, RS485, RS232, or TTL Remote Control
| Environmenta:l |
|
Operating Temperature: |
0
- 50°C (40°C @ 10,000 Feet) |
|
Relative Humidity: |
95%
(non-condensing) |
| Operating
Altitude: |
10,000
feet maximum |
| Non-operating
Temp: |
-20
to 70°C |
| Non-operating
Altitude: |
50,000
feet maximum |
|
|
| RF
Specifications: |
|
| Spurious
Outputs:
|
-40
dBc, maximum.
-50
dBc, available.
|
|
Input Impedance: |
50
Ohms, VSWR 2.0:1
|
| Output
Impedance: |
50
Ohms, VSWR 2.0:1
2.5:1
maximum.
|
|
Input Connector: |
Type
N (Female). |
|
Output Connector: |
1.0
to 2.5 GHz
1 5/8" coax,
2.0 to 4.0 GHz, WRD 200
4.0 to 8.0 GHz, WRD350
8.0 to 12.0 GHz, WR90
12.0 to 18.0 GHz, WR62
7.5
to 18.0 GHz, WRD750
6.0 to 18.0 GHz, WRD650
(Other Waveguide is Available Option 117) |
|